logo
products

STT-15A 250V Aupo Thermal Fuse Thermal Cut Off Fuse For Water Heater

Basic Information
Place of Origin: China
Brand Name: RFan
Certification: UL.TUV.ROHS
Model Number: STT-15A
Minimum Order Quantity: 2000PCS
Price: 0.03-0.5
Packaging Details: 1000/Bag
Delivery Time: 5-7days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1KK/M
Detail Information
Certifications: UL, CSA, TUV Rated Functioning Temp: 76 °Cto 230 °C
Fuse Type: Non-Resettable Key: Thermal Cutoff
Holding Temperature: 150°C Lead Length: Standard
Highlight:

250V Aupo Thermal Fuse

,

Water Heater Aupo Thermal Fuse

,

250V Thermal Cut Off Fuse


Product Description

STT-15A 250V Big Current Thermal Fuse Aupo Thermal Fuse Thermal Cut Off Fuse For Water Heater

NO.STT-15A Series
Features
With strong compact structures,high
Insulation resistance and quickly heated
advantages can be quickly action.
When the products work under abnormal or
can't be reset,can soon cut off the power.
 
Applications
Widely used in follow various field such as transformer,
exhaust fan,fan and small power motor charger,adopter,
secondary battery,household combined with gas water
heater lightings and various heater equipment.
 
Dimension (unit:mm)
STT-15A 250V Aupo Thermal Fuse Thermal Cut Off Fuse For Water Heater 0
Electrical characteristics at 25℃
No. Part

number
Tf Operating

temperature

Th

Tm
Ir lp Voltage Approvals
(℃) (℃) (℃) (℃) (A) (A) (V) UL CCC TUV PSE VDE CB
1 STT073C 73 71±2 43 130 15A 150 250Vac O O O O O
2 STT077C 77 74±2 47 130 15A 150 250Vac O 0 O   0
3 STT113C 113 108+3 83 160 15A 150 250Vac O O O 0 O
4 STT121C 121 117±3 91 160 15A 150 250Vac O O O O O
5 STT133C 133 129+3 103 160 15A 150 250Vac O O O 0 O
6 STT142C 142 138±3 112 170 15A 150 250Vac O 0 O 0 0
7 STT157C 157 152±3 127 170 15A 150 250Vac O O O O O
8 STT167CC 167 164+3 137 190 15A 150 250Vac O O O 0 O
9 STT172C 172 169±3 142 190 15A 150 250Vac O O O 0 O
10 STT184C 184 180±3 154 210 15A 150 250Vac O O O 0 O
11 STT216C 216 213±3 186 260 15A 150 250Vac O O O 0 O

 

= Approved =Going on
Tf Functioning temperature,the standard tolerance:+0,-5
Th holding temperature:Maximum durative exposed exposed temperature.
Tm maximum temperature:The highest temperature at which the thermal link wont change the condition

Contact Details
sunny

Phone Number : +8613954571920

WhatsApp : +8613954571920